FG 40 Ex

ATEX and IECEx certified: Incremental encoder with a solid shaft

The incremental encoder Ex FG 40 with a solid shaft design is an rugged and at the same time reliable device for measuring speed that has been constructed for use in hazardous areas in heavy industrial applications. As a further development of the proven FG-40 series it is designed to offer extremely high resistance to shock and vibration loads as well as ingress protection IP66 (salt water proof casing). Resolution as high as 62500 pulses per revolution ensures precise measurement results even in harsh conditions. The encoder is optionally equipped with 2 systems, as desired with HTL, TTL or sin/cos signal output respectively. The flameproof casing with detachable terminal box cover facilitates connecting the cable during on site installation. That in turn means it is possible to use different cable lengths to connect the same device type. The encoder is certified to EN 60079 (ATEX) and IEC 60079 (IECEx) for applications in Zones 1 and 2 (gas) as well as Zones 21 and 22 (dust).

 

Diameter solid shaft

11 mm or 14 mm

Supply voltage

12 - 30 VDC

Signal amplitude

HTL, TTL, Sin/Cos

Basic pulse rates for HTL, TTL and Sin/Cos

1000, 1024, 1200, 2000, 2048, 2400, 2500

Interpolation factors for HTL/TTL

1, 2, 4, 8, 10, 20, 25

Output signals

0°, 90°, N, error and inverted signals

Maximum frequency

200 kHz

Device temperature range

-40 °C bis +60 °C (T6 bis +55 °C)

Degree of protection

IP66

Weight

Approx. 3.9 kg

Special features

ATEX and IECEx certified to EN/IEC 60079

Gas: II 2G Ex db IIC T6-T5 Gb

Dust: II 2D Ex tb IIIC T85°C Db IP6x

Important information

Cable glands and blanking plugs are not included in the scope of supply; however, they can be ordered as accessory parts. It is only permitted to use cable glands and blanking plugs that have been certified for the respective application in accordance with the standards EN/IEC 60079-0 and EN/IEC 60079-1 (gas) or EN/IEC 60079-31 (dust).

Option AK

A  connection system with terminal strips

Option AKK

Two connection systems with terminal strips

Option AH

HTL signals 0°, 90°, reference pulse, error; all respective signals with inverted signals

Option AT

TTL signals 0°, 90°, reference pulse, error; all respective signals with inverted signals

Option SH

1 Vpp signals sine, cosine, reference pulse; error as HTL signal; all respective signals with inverted signals

Option ST

1 Vpp signals sine, cosine, reference pulse; error as TTL signal; all respective signals with inverted signals

Operating and Assembly Instructions (PDF, 3.69 MB) Download
Flyer Ex FG 40 (PDF, 436 KB) Download
Inquiry form - Ex FG 40 (PDF, 46 KB) Download
Product Article Ex FG 40 (PDF, 180 KB) Download
Product article series FG(H) 40 (PDF, 178 KB) Download
ATEX certificate (PDF, 1.68 MB) Download
IECEx certificate (PDF, 6.09 MB) Download

Note