Pulse converters | HTL ↔ TTL

Accessories – electronic

  • Converts HTL in TTL or TTL in HTL
  • Signal level conversion, eliminate interference signals
  • Input and output electrically isolated by means of optocouplers
  • Options: Supply voltage 5 V or 12-30 V

The pulse transformers

Pulse converters are utilized for purposes of electrical isolation, signal level conversion and elimination of interference signals; they also convert HTL to TTL as well as TTL to HTL. The output stages are equipped with the latest driver ICs, and enable signal transmissions along long lengths of cables in conjunction with high output frequencies. Optocouplers isolate the inputs from the outputs. Short-circuits and output stage overload are signalled. The modules can be snapped onto standard mounting rails EN 50 022.

Technical Data

AttributeValue
Product Usage

Encoder signal outputs, convert (HTL in TTL or TTL in HTL)

Supply Voltage

12-30 VDC

Signal Input

HTL (square wave 12-30 V) or TTL (square wave 2.8-6 V)

Signal Output

HTL or TTL (0°, 90°, N and respective inverted signals)

Frequency Range

0 - 250 kHz

Casing

Electronic housing for standard mounting rail

Dimensions

50 x 75 x 52 mm

Device Temperature Range

-20 °C to +70 °C

Degree Of Protection

IP20

Electrical Connection

18 pole PHOENIX COMBICON screw terminals 2.5 mm²

Device Options

Isolated conversion of HTL in TTL or vice versa with different supply voltages

  • OM 3-1-1: HTL/HTL: 12 - 30 V
  • OM 3-1-2: TTL/HTL: 12 - 30 V
  • OM 3-1-3: HTL/TTL: 5 V
  • OM 3-1-4: TTL/TTL: 5 V
  • OM 3-1-5: HTL/TTL: 12 - 30 V
  • OM 3-1-6: TTL/TTL: 12 - 30 V
Mechanical Options
Special Features And Certificates

News

Contact

We look forward to taking on your challenges.

Sales

Newsletter
Information about privacy concerns can be found in our Privacy Policy